MX-50 Moisture Analyser

MX-50 Moisture Analyser

Product Details:

  • Size 202(W) x 336(D) x 157(H) mm
  • Application Food, Pharmaceuticals, Chemicals, Environmental Analysis
  • Interface RS-232C
  • Usage Laboratory/Industrial Moisture Analysis
  • Function Moisture Content Analysis, Drying, Weighing
  • IP Rating IP20
  • Connectivity Type Wired
  • Click to View more
X

MX-50 Moisture Analyser Product Specifications

  • ABS (Body), Stainless Steel (Pan)
  • RS-232C
  • Wired
  • Laboratory Moisture Balance
  • Food, Pharmaceuticals, Chemicals, Environmental Analysis
  • 220V/50Hz AC
  • White
  • 0.001g (1mg)
  • Moisture Analyser
  • 0.001g - 51g
  • IP20
  • 202(W) x 336(D) x 157(H) mm
  • Moisture Content Analysis, Drying, Weighing
  • Max 51g
  • Quick Drying, Multiple Measurement Modes, In-built Programs
  • Digital VFD
  • Laboratory/Industrial Moisture Analysis
  • Automatic
  • VFD (Vacuum Fluorescent Display)
  • Mains
  • Up to 20 programs
  • 5C-40C
  • 0.01%
  • 1-480 minutes
  • GLP/GMP/ISO Compliant
  • 0.05% (2g sample), 0.02% (5g sample)
  • Halogen Lamp
  • 85mm diameter
  • 80% RH or less (no condensation)

Product Description

Technical Specification

Measurement Method

400 W straight halogen lamp heating system with SRA filter and SHS weighing technology

Max Sample Weight Capacity

51 g

Weight Resolution

0.001 g

Moisture Content Display

0.01% / 0.1%

Moisture Content Accuracy over 1g

0.10%

(Standard Deviation) over 5g

0.02%

Heating Technology

Halogen lamp (Straight type, 400 Watt max, 5000 hours)

Drying Temperature (1°C increment)

50-200°C

Memory of Measurement Programs

20 sets

Measurement Programs

Standard Mode/Automatic Mode/Quick Mode/Timer Mode/Manual Mode

Measurement Mode

Moisture content(Wet or Dry base) /Dry content/Ratio/Weight

Heating Mode

Standard / Quick / Step /Ramp

Display Type

Large VFD

Interface

RS-232C standard

Data Memory Function

100

Operating Temperature

5-40°C (41-104°F) less than 85%RH

GLP/GMP/ISO

Available

Self Check Function

Standard

Communication Software

WinCT-Moisture standard

Sample Pan Size

Ø85 mm

Power

AC 200V to 240V (1.5A), 50/Hz, Approx. 400W

Physical Dimention/Weight

215(W) x 320(D) x 173(H) / Approx. 6 kg

Standard Accessories

Sample Pans - 20, Pan Handles -2, Spoon, Test Sample (30g of Sodium Tartrate Dihydrate), CD-ROM (WinCT-Moisture), Glass Fiber Sheet, RS-232C Cable, Display Cover, Dust Cover, Instruction Manual, Quick Reference Card, Power Cable, Fuse



Accurate Moisture Analysis for Diverse Applications

The MX-50 Moisture Analyser ensures consistently precise measurements, making it invaluable in food, pharmaceutical, chemical, and environmental testing. Its halogen lamp provides rapid heating and uniform drying, ensuring efficiency in routine analyses. The intuitive VFD display simplifies operation, while the robust memory supports up to 20 preset programs for ease of use.


Designed for Reliability and Compliance

Constructed with a durable ABS body and stainless steel pan, the MX-50 is IP20-rated for safe laboratory or industrial environments. It outputs GLP/GMP/ISO-compliant data, making record-keeping straightforward. The device functions in a broad temperature and humidity range, adapting to different working conditions and requirements.

FAQs of MX-50 Moisture Analyser:


Q: How does the MX-50 Moisture Analyser determine moisture content in samples?

A: The MX-50 uses a halogen lamp to rapidly heat and dry the sample placed on its stainless steel pan. It calculates the moisture content based on the change in weight before and after drying, displaying results digitally with 0.01% readability.

Q: What types of samples and industries can the MX-50 be used for?

A: The MX-50 is suitable for a wide array of samples including food, pharmaceuticals, chemicals, and environmental materials. It accommodates laboratory and industrial applications where precise moisture content analysis is required.

Q: When should the memory and timer features be used?

A: The memory feature, which holds up to 20 programs, is ideal for repetitive testing procedures, allowing you to save and recall frequently used drying methods. The timer range (1-480 minutes) lets you set optimal drying durations for different sample types and methods.

Q: Where can data from the MX-50 Moisture Analyser be outputted or stored?

A: Data can be transferred via the RS-232C interface, supporting GLP/GMP/ISO-compliant record-keeping. This makes it easy to document test results or integrate them into external data management systems within laboratory or industrial setups.

Q: What benefits does the halogen lamp provide in the moisture analysis process?

A: The halogen lamp ensures quick and uniform sample drying, reducing analysis time significantly. Its efficiency minimizes thermal degradation, delivering repeatable and accurate moisture content results for various materials.

Q: How does the MX-50 maintain accuracy and repeatability in measurements?

A: With a high accuracy of 0.001g and a repeatability of 0.05% (2g sample) or 0.02% (5g sample), plus a regulated temperature and advanced weighing mechanism, the MX-50 delivers consistently reliable measurements even across multiple analyses.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+